Triple Pole 50/65ka MCCB Molded Case Circuit Breaker

Rated Frequency:50/60Hz
Breaking Capacity:65ka
OEM:Available
Rated Voltage:400V, 230/400V AC
Availability:
Quantity:
  • SWM1

  • SINGI

Product Description

APPLICATION
Molded case circuit breakers (MCCBs) are overcurrent protection devices used in power distribution systems to protect circuits and equipment from damage caused by excess current. The SWM1 MCCB has a rated insulation voltage of 800V and is suitable for AC power systems operating at 50 or 60 Hz with rated voltages up to 690V and rated currents up to 1250A, for non-frequent switching. It incorporates overload, short circuit and undervoltage protection functions to disconnect the circuit upon detection of a fault condition to prevent damage to the circuit and connected equipment. According to their rated ultimate short-circuit breaking capacities, MCCBs can be categorized into Type C (basic), Type L (standard), Type M (high-breaking), and Type H (higher-breaking). The SWM1 MCCB is characterized by a compact size, high breaking capacity, short arcing time and vibration resistance. This makes it an ideal solution for land and marine applications.The SWM1 MCCB can be installed either vertically or horizontally. It complies with IEC 60947-2 and GB 14048.2 standards. MCCBs provide fundamental protection for low-voltage electrical distribution systems. They help minimize damage and service interruptions caused by excess currents, thereby improving power reliability and safety. The overload protection function of the SWM1 MCCB prevents overheating and damage due to prolonged overcurrents within the thermal limits of the conductors. Its short-circuit protection activates instantaneously upon detection of overcurrents exceeding its rated ultimate breaking capacity to isolate the fault, limiting damage to components like busbars or cables. Undervoltage protection guards against problems such as overheating, damage, or maloperation that can arise from operation at below a lower voltage threshold.

 

TECHNICAL PARAMETERS

 

 

   Model

 

Rated

Current

(A)

 

 

Poles

Rated

 

Rated

Insulation

Voltage

(V)

 

Rated

Voltage

(V)

 

Electric

Arcing

Distance

(mm)

Rated

Limit

Short circuit

Breaking

Capacity

(KA)

Rated

Working

Short

-circuit

Breaking

Capacity

(KA)

O performance

Performance (Times)

On-power Off-power

SWM1-63L

6,10,

16,20,

25,32,

40,50,

63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2,3,4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  800

400

0

25

18

6000

8500

 

SWM1-63M

 

 

690v

and

below

50

35

SWM1-100C

10,16,

20,25,

32,40,

50,63,

80,100

25

18

SWM1-100L

 

 0(<=50)

35

22

SWM1-100M

50

35

SWM1-100H

85

50

SWM1-225C

100,125,

140,160,

180,200,

225

400

 

 

 

<=50

25

18

2000

7000

SWM1-225L

 

 

 

 

 

 

690v

and

below

35

22

SWM1-225M

50

35

SWM1-225H

85

50

SWM1-400C

225,250,

315,350,

400

35

25

1000

4000

SWM1-400L

50

35

SWM1-400M

 

 

 

 

<=100

65

42

SWM1-630C

 

400,500,

630

35

25

SWM1-630L

50

35

SWM1-630M

65

42

SWM1-630H

100

65

SWM1-800M

630,700,

800

75

50

1000

2500

SWM1-800H

100

65

SWM1-1250H

800,1000,

1250

 <=120

100

65

1000

2000



THERMAL RELEASE WITH  INVERSE TIME LAG

Ui of release

(A)

Thermal breaking release  (40for land,45°Cfor ship)

Electromagnetic release breaking current(A)

Remark

1.05In(cool station)no breaking time(h)

1.30(thermal station) breaking time(h)

10<In<63

>=1

<1

10In±20%

Power distribution

63<In<100

>=2

<2

100<In<630

>=2

<2

5In±20%&10In±20%

Power distribution

10<In<630

1.0In(cool) no breaking time(h)

1.20In(thermal) breaking time(h)

12In±20%

Motor protection


MCCB

MCCB

MCCB

MCCB

MCCB

MCCB

MCCB

MCCB

MCCB

MCCB

MCCBMCCB

MCCB

MCCB

MCCB


Previous: 
Next: 

Product Category

Singi Electrical, founded in 1995, is a high-tech enterprise which specializing in manufacturing and marketing of low-voltage circuit breakers...

INFORMATION

OUR PRODUCTS

CONTACT US

Phone:+86 0577 62053322
Whatsapp:+86 18858868106
Email:singi99@singi.com
GET IN TOUCH WITH US
                                                                                                                                                                                浙ICP备07016448号-2
©ZHEJIANG SINGI ELECTRICAL LLC.   All rights reserved Sitemap.